Rusted, seized bolts are the job that turns a 10-minute repair into an afternoon. The M-T CPH-01 uses high-frequency magnetic induction to heat the bolt itself — not the surrounding parts — expanding the fastener and burning out rust so it breaks free cleanly. No torch, no open flame, no heat damage to nearby paint, wiring, or plastics.
One-handed operation, super easy to use.
Why Induction Heating
- Heats the bolt, not the part — the magnetic field induces current directly in the ferrous fastener, so surrounding components stay cool
- No open flame — safe near fuel lines, wiring harnesses, and plastics where a torch is not
- Fast — small fasteners release in seconds; the bolt expands and rust turns to powder
- One-handed operation — hold the tool and work the fastener with your other hand free
Specifications
| Item | Detail |
|---|---|
| Model | CPH-01 |
| Working principle | High-frequency magnetic induction heating |
| Recommended bolt heating range | 300–500 °C (572–932 °F) |
| Maximum recommended temperature | Below 500 °C — see warning below |
| Duty cycle | Up to 10 minutes continuous use, then allow the unit to cool |
| Overheat protection | Built-in thermal protection |
| Operation | One-handed |
Temperature Warning
Heating temperature: below 500 °C.
The recommended bolt heating range is 300–500 °C. Exceeding 550 °C may cause metal parts to anneal, directly impairing their mechanical properties. Therefore, heating below 500 °C is recommended.
Coil rule: the coil diameter must be at least 5 mm larger than the bolt diameter. An undersized coil will not couple properly and can overheat the tool.
Coil Selection Chart
| Coil diameter (mm) | 15 | 20 | 25 | 30 | 35 | 40 | 45 |
|---|---|---|---|---|---|---|---|
| Max bolt diameter (mm) | 10 | 15 | 20 | 25 | 30 | 35 | 40 |
Coils are available in U-form, round, and other shapes. The flexible tips are easy to bend to fit the work angle — bend them around bolts, studs, hoses, pipes, or other fittings.
How to Use
- Choose the right coil — diameter at least 5 mm larger than the bolt; shape that fits the access angle
- Fit the coil over the bolt — keep the coil centered on the fastener, not touching surrounding metal parts
- Power on and heat in short bursts — watch the bolt glow; 300–500 °C is enough for the rust to break down
- Remove the bolt with a wrench — while hot, the rust bond is broken and the fastener turns
- Wear gloves — the bolt and the coil both stay hot after use
Helpful Tips
- If the device is releasing constantly during operation and the indicator light changes from white to red, the temperature has reached the protection threshold and overheat protection has been activated — wait 30–60 seconds for the cooling fan, then resume.
- When using the coil, wear gloves to prevent sticking your hands to hot metal.
- Do not touch the coil or the heated bolt during and right after use.
- Never use incompatible coils — non-original parts may burn out due to parameter mismatch.
Troubleshooting
| Problem | Likely cause | What to do |
|---|---|---|
| Device fails to start | Power issue | Check the power cord is fully plugged in and the outlet is working |
| Device fails to start | Switch not confirmed | Confirm the power switch is ON and the power cord is undamaged |
| Device shuts off unexpectedly | Overheat protection triggered | Wait for it to cool completely before restarting; if it triggers frequently, check for blocked vents and clean any dust |
| Low heating efficiency or no heating | Heating coil issue | Inspect the coil for damage, oxidation, or poor contact; polish contacts with fine sandpaper and reinstall |
| Low heating efficiency or no heating | Coil not connected securely | Ensure the coil is securely connected to the device ports; reseat and confirm no loose connections |
| Low heating efficiency or no heating | Induction module failure | Try replacing with a known-good coil; if it still fails, the induction module may be faulty — contact support |
| Device shuts off unexpectedly | Cooling system blocked | Clean dust and debris from vents to ensure airflow; check the fan is working |
| Coil burns out or shorts | Improper use | Do not continuously keep heating at maximum; do not use in damp or dust-heavy environments |
| Coil burns out or shorts | Incompatible parts | Use only original compatible coils |
Safety Precautions
- Keep out of reach of children.
- Unplug when not in use.
- The heating coil becomes extremely hot — never touch it during or right after operation.
- Wear heat-resistant gloves during use.
- Do not use in wet or dusty environments.
- Do not continuously operate at maximum output beyond the 10-minute duty cycle.
- Keep vents clear; the cooling fan must be able to move air.
FAQ
Q: Will it work on stainless steel bolts?
A: Induction heating works best on ferrous (magnetic) metals such as ordinary carbon steel bolts. It also works on many stainless bolts, but more slowly — stainless conducts magnetic energy less efficiently. Non-magnetic metals like aluminum will not heat.
Q: Can I use it near the fuel tank or fuel lines?
A: That is exactly one of its advantages over a torch — there is no open flame. Still, keep combustibles clear and follow normal workshop safety practice.
Q: Why did my coil burn out?
A: The two most common causes are using an undersized coil (must be at least 5 mm larger than the bolt) and non-original coils with mismatched parameters. Both are covered in the guide above.
Q: How long can I run it continuously?
A: Up to 10 minutes of continuous use, then let the unit cool. If overheat protection trips, wait 30–60 seconds for the cooling fan and resume.
Q: The bolt won’t come loose even after heating — what now?
A: Re-check that the coil diameter is at least 5 mm larger than the bolt and that the coil is centered. Penetrating oil applied before heating, then heating while the oil wicks in, gives the best result on heavily rusted fasteners.
Warranty & Support
The CPH-01 is covered by the M-T limited warranty. Registration is optional — your warranty rights are not affected. Warranty details and registration →